Usage. Infrared Radiator tubes (or IR tubes) are used in DryStar units of the Heidelberg® Speedmaster® SM 52, SM/CD 74, SM/CD 102, and XL 105 machines. In order to ensure maximum longevity and durability, we recommend the replacement of the IR tubes every 5,000 hours.

Quality defines the result. Every ink needs a special wavelength so as to be fl uidized and to infiltrate the paper before it hardens via oxidation. In this regard, the production methods used for the Heidelberg IR tubes will guarantee excellent results.

Our IR tubes use a special gold alloy that focuses the IR light onto the paper, so your machine will not dangerously heat up. They meet the highest quality standards, which means they are without any bubbles and brush marks in the glass to avoid any risk of fraction due to the machine vibrations. All used cables have triple C standard, to prevent machine shutdown due to flashover.

Additionally, Heidelberg IR tubes use tantalum disks instead of halogen to absorb the splitting of Wolfram parts. The result: Less deposit on the glass (typical black color) and the tubes will last much longer.


 